# ModTOS
|
||||
|
||||
Modbus RTU driver for STM32 + FreeRTOS with interrupt-driven frame handling and RS485 GPIO direction control.
|
||||
**Modbus RTU Driver for STM32 + FreeRTOS**
|
||||
*Interrupt driven frame handling with RS485 GPIO direction control*
|
||||
|
||||
---
|
||||
|
||||
## Overview
|
||||
|
||||
ModTOS is a lightweight, dependency-free Modbus RTU slave implementation intended for use in embedded systems based on STM32 and FreeRTOS. It is designed to operate as a cooperative background task, minimizing CPU usage and avoiding interference with time-sensitive application logic.
|
||||
**ModTOS** is a lightweight dependency free Modbus RTU slave implementation designed for STM32 microcontrollers running FreeRTOS. It acts as a cooperative background task minimizing CPU load and avoiding interference with timing critical logic.
|
||||
|
||||
The driver uses interrupt-based UART reception with idle line detection to capture complete RTU frames without polling. RS485 transceiver direction is controlled via a user-defined GPIO pin, allowing the driver to support half-duplex serial communication in industrial settings.
|
||||
The driver leverages **UART interrupt with idle line detection** to capture Modbus RTU frames without polling. RS485 direction is controlled via GPIO enabling half duplex communication commonly found in industrial systems.
|
||||
|
||||
ModTOS exposes a flat holding register table accessible through standard Modbus function codes `0x03` Read Holding Registers and `0x10` Write Multiple Holding Registers.
|
||||
|
||||
---
|
||||
|
||||
## Features
|
||||
|
||||
- Function Code 0x03 Read Holding Registers
|
||||
- Function Code 0x10 Write Multiple Holding Registers
|
||||
- CRC-16 validation and exception handling
|
||||
- Flat register buffer 128 x `uint16_t`
|
||||
- Task-based integration with optional stats tracking
|
||||
- No dynamic memory allocation
|
||||
- Easily adaptable to polling or non-RTOS environments
|
||||
- Modbus RTU Slave one unit ID per UART
|
||||
- **Function Code 0x03** Read Holding Registers
|
||||
- **Function Code 0x10** Write Multiple Holding Registers
|
||||
- CRC 16 Modbus validation on all frames
|
||||
- Modbus Exception Handling:
|
||||
- `0x01` ILLEGAL_FUNCTION
|
||||
- `0x02` ILLEGAL_DATA_ADDRESS
|
||||
- `0x03` ILLEGAL_DATA_VALUE
|
||||
- Flat register buffer 128 x uint16_t
|
||||
- Task based integration with FreeRTOS
|
||||
- Zero dynamic memory allocation
|
||||
- Uses **UART Receive to Idle** mode no polling
|
||||
- Portable to bare metal & polling environments with minimal changes
|
||||
|
||||
## Integration Notes
|
||||
---
|
||||
|
||||
- Requires UART configured with idle line detection
|
||||
- GPIO pin needed for RS485 DE/NRE control
|
||||
- Designed for projects where Modbus functionality must coexist with high-speed control tasks
|
||||
## High Level Design
|
||||
|
||||
### 1 Global Modbus Register Table
|
||||
- Represents Modbus holding registers starting at address 0
|
||||
- Accessible directly by application code or via Modbus transactions
|
||||
|
||||
### 2 UART RX & TX Buffers
|
||||
- `request_frame` holds raw Modbus RTU request bytes
|
||||
- `response_frame` used to construct replies
|
||||
- Both statically sized for worst case message sizes
|
||||
|
||||
### 3 RS485 Direction Control
|
||||
- DE and RE pin sets transceiver mode:
|
||||
- **RX default**
|
||||
- **TX only during response transmission**
|
||||
|
||||
---
|
||||
|
||||
## Execution Flow
|
||||
|
||||
### 1 Initialization
|
||||
- Clears buffers
|
||||
- Sets RS485 to **RX mode**
|
||||
- Enables UART in **idle line receive** mode
|
||||
|
||||
### 2 Receiving a Frame
|
||||
- UART receives bytes into `request_frame`
|
||||
- Idle line detection triggers reception complete callback
|
||||
- Application must implement callback to forward the frame for parsing
|
||||
|
||||
### 3 Processing the Request
|
||||
- Frame validation:
|
||||
- Minimum length
|
||||
- Slave ID match
|
||||
- CRC 16 check
|
||||
- Dispatch to appropriate handler:
|
||||
- `0x03` Read holding registers
|
||||
- `0x10` Write multiple holding registers
|
||||
- Others Modbus exception
|
||||
|
||||
---
|
||||
|
||||
## Function Code Handlers
|
||||
|
||||
### FC 0x03 Read Holding Registers
|
||||
- Parses `startAddr` and `numRegs`
|
||||
- Validates bounds
|
||||
- Builds response:
|
||||
- Slave ID
|
||||
- Function code
|
||||
- Byte count
|
||||
- Register values High byte Low byte per register
|
||||
- CRC
|
||||
|
||||
### FC 0x10 Write Multiple Holding Registers
|
||||
- Parses `startAddr` `numRegs` and `byteCount`
|
||||
- Validates range and byte consistency
|
||||
- Writes values to register table
|
||||
- Responds with echo:
|
||||
- Slave ID
|
||||
- Function code
|
||||
- Start address
|
||||
- Quantity
|
||||
|
||||
---
|
||||
|
||||
## Response Transmission
|
||||
|
||||
- Appends CRC to `response_frame`
|
||||
- Sets RS485 to **TX mode**
|
||||
- Sends frame via **blocking UART**
|
||||
- Switches RS485 back to **RX mode**
|
||||
- TX timeout currently fixed at **100 ms**
|
||||
|
||||
---
|
||||
|
||||